Ship Specifications

Displacement: 66,000 tons of water. The Titanic had 4 funnels (smokestacks). Each was 62 feet tall and had a diameter of 22 feet. The distance from keel to top of funnels was 175 feet. The rudder was 78 feet high, weighed about 101 tons and was cast in 6 separate pieces. Titanic's 3 anchors had a combined weight of 31 tons.

Get A Quote

Format No. FP

Boiler 70 TPH 1.85 75 75 ESP ESP 10.05.2019 02.30 PM 1,40,508 96,696 50 34 34. Coal Crusher 0.5x 0.4 15.20 15.20 Pulse jet bag filter Pulse jet bag filter 07.05.2019 09.15 AM 20,000 6,984 50 24 35. 100 KVA D.G. Set 0.127 8.0 8.0 Chimney Chimney Not running -- 36. Boiler 42 TPH

Get A Quote

What Does It Mean When White Smoke Comes Out of My …

White smoke coming from your chimney flue is actually steam produced from condensation as a byproduct of fuel burning. It's common to see the smoke and think there's something wrong with your chimney, but this is not the case. The clouds are a normal part of fireplace or boiler operation and shouldn't be cause for concern.

Get A Quote

NBE PELLETS SYSTEM

Exposed fuel may not be in the boiler room, except logs. Do not exceed 4.75 m3 fuel in the boiler room, including fuel storage and usage storage 9. Prohibited liquids and materials in boiler room. The boiler room must be kept clean and contain no combustible materials nor flammable liquids (except oil …

Get A Quote

LNER Class P2 - Wikipedia

No. 2005 lacked the Kylchap double chimney of the rest of the class, and No. 2006 had a different boiler design, with a longer combustion chamber, and firebox heating area and volume of 253 sq ft (23.5 m 2) and 319 cu ft (9.0 m 3) respectively with a Robinson superheater. The production series was completed in 1936. [citation needed]

Get A Quote

Boiler Flues, Flue Extension & Chimney cowls

The all new Worcester Greenstar gas-fired Si Compact is the successor to the Greenstar Si combi boiler. Ideal for apartments and small to medium sized properties with one bathroom, it has a host of performance-enhancing features, including the revolutionary WB7 heat exchanger which enables the appliances to deliver DHW flow rates of 10.2 and 12.3 l/min despite their compact size.

Get A Quote

Questions answers & calculation on Boiler draught & Chimney

19/04/2021 · We have excess air EA = O2 X 100 / (21-O2) EA = 4.7 X 100 / (20-4.7) EA = 30.71% 2-Calculate the Oxygen level (O2) in flue gas, if excess air is 25% We have Excess air EA = O2 X 100 / (21-O2) 25 = O2 X 100 / (21-O2) O2 = 4.2% 3-A Boiler's combustion system requires 5.5 kg of air for burning 1 kg of fuel, then calculate the total air required for complete combustion if its flue gas has 4.1%

Get A Quote

West Burton power stations - Wikipedia

The West Burton power stations are a pair of power stations on the River Trent near Gainsborough, Lincolnshire, England.One is a coal-fired power station, which was commissioned in 1966, and the second is a combined cycle gas turbine power station, commissioned in 2013. Both stations are owned and operated by EDF Energy.. The station has been accredited as an Investor in People since 1995 and

Get A Quote

Boiler Chimney Venting | Hearth.com Forums Home

23/07/2010 · The Chimney has a Complete Cover over Both Flues. The Fireplace Flue has a complete Pellet Stove Liner through. The Flue to the Boiler does not have its own cap. Have not had this happen before and have had the smae boiler venting since it was installed 15 years ago. I was assuming there are some cracks at the level around the fireplace.

Get A Quote

Combustion optimization in PF Boilers

Air required to burn carbon completely= 2.67*4.32*38=438 tons of air/100 tons of fuel H2 + 1/2O2 ---H2O: H=2.3% = 32/4 =8 tons of O2 per ton of H Air required to burn Hydrogen completely =8*4.32*2.3=78 tons of air/100 tons of fuel S + O2-----SO2: S=0.2% = 32/32=1 tons of O2 per ton of S